-24%
,

ANTSPACE HK3 V6

Availability:

4 in stock


The Bitmain with EC2-DT Antbox is a modular mining container. It uses standard container construction, after connecting electricity and network you can mine bitcoins right away. It can greatly reduce the cost of building a mining farm. It is easy to transport and quick to deploy once it arrives on site.

Shipping availability to Central Europe and Russia

Offer valid for the last 2 units

Delivery 5 to 30 days after order within the United States (check delivery or export times).

$65,000.00 $85,000.00

4 in stock

Product Overview
Model ANTSPACE HK3 V6
Dimensions (L*W*H) (mm) 6058*2438*2896
Miner Capacity 210 units -S19 Hyd. & S21 Hyd. Series miner
Container Certification China Classification Society Certification
Safety Certification NFPA 79:2021
UL 508A:2018 R8.21
CSA C22.2 No. 14-18
ANSI/ISO 12100:2012
IEC 60204 Ed 5.1 2009
Operating Power(kW) 1047~1050
PUE(Power Usage Effectiveness) 1.022(Excluding cooling tower)/1.032(Including cooling tower)
Input Voltage and Frequency 400V±5% 50/60Hz
Detailed Characteristics
Shipping Weight(T) 8
Operating Weight (T) 12
Main Switch of Power Distribution Cabinets(A) 1200*2
Rated Current(A) A:952; B:866
Rated Current per Miner(A) 10
Inlet Cable The inlet cables can withstand high-voltage of above 600V, with the following requirements:
L1 single core cable 600kcMil(300mm²)x4
L2 single core cable 600kcMil(300mm²)x4
L3 single core cable 600kcMil(300mm²)x4
N Single-core cable 600kcMil(300mm²)x4
PE single-core cable 500kcMil(240mm²)x2
Connection Interface(Cooling Tower) DN100(ISO2852 PN16)
Connection Interface(Plate Heat Exchage Interface) DN100(GB/T 9122-2010 PN16 DN100)
Flow Rate(m³/h) >85
Quantity of ANTSPACE powered by one 2500kVA Transformer 2

Specification Details For Dry-Wet Towers

Product Overview
Type Dry-Wet Tower Container Type (EC1 – DWT)
Dimensions(L*W*H)(mm) 6058*2438*2896
Heat Dissipation Capacity(kW) 1000
Outlet Temperature @ 28℃ Wet Bulb Temperature 35℃
Container Certification China Classification Society Certification
Safety Certification NFPA 79:2021
UL 508A:2018 R8.21
CSA C22.2 No. 14-18
ANSI/ISO 12100:2012
IEC 60204 Ed 5.1 2009
Operating Power(kW) 14~28
Motor Rated Voltage and Frequency 400V±5% 50/60Hz
Detailed Characteristics
Shipping Weight(T) 7
Operating Weight(T) 13
Connection Interface DN125(ISO2852 PN16)
Water Resupply Pipe Interface DN40(Internal thread)
Drain Pipe Interface DN65(Internal thread)
Noise Level @25℃, 15m 70dBA
Water Consumption(m³/h) 0.7~1.3m³/h

 

Specification Details For Dry Cooler Towers

Product Overview
Type Dry Cooler Towers Container Type (EC2 -DT)
Number 2
Dimensions(L*W*H)(mm) 6058*2438*2896
Outlet Temperature @ 30℃ ambient temperature 35℃ (Outlet temp 5℃ above ambient temp)
Container Certification China Classification Society Certification
Operating Power(kW) 20~32
Motor Rated Voltage and Frequency 400V±5% 50/60Hz
Detailed Characteristics
Shipping Weight(T) 6
Operating Weight(T) 8
Connection Interface DN100(ISO2852 PN16)
Water Resupply Pipe Interface DN10(Tapered tube)
Noise Level @25℃, 15m 70dBA
Pipe materials 304 stainless steel

Specification Details For Plate Heat Exchanger

Product Overview
Type Plate Heat Exchanger (EC3 – PHE)
Dimensions(L*W*H)(mm) 775*480*1069
Material TI
Detailed Characteristics
Shipping Weight(KG) 379
Operating Weight(KG) 461
Connection Interface DN100(GB/T 9122-2010 PN16 DN100)
External circulation supply liquid temperature (℃) 0~30
External circulation flow rate (m³/h) 33~110
Internal circulation flow rate (m³/h) 100

SKU: EM34254 Categories: ,