ANTRACK V2


Model ANTRACK
Version V2
Capacity 4 units ANTMINER (Hydro) or
4 units ANTMINER (U2 Hydro) or
2 units ANTMINER (U3 Hydro)
Maximum load,kW 24

$8,800.00

Product Glance Value
Model ANTRACK
Version V2
Capacity 4 units ANTMINER (Hydro) or
4 units ANTMINER (U2 Hydro) or
2 units ANTMINER (U3 Hydro)
Maximum load,kW 24
Detailed Characteristics Value
Part 1: Mining Cabinet
Hardware Configuration
Size (Length*Width*Height), mm (without package) 1200*600*1300
Size (Length*Width*Height), mm (with package) 1460*1330*780
Net weight, kg (without package) 130
Gross weight, kg (with package) 185
Network connection mode RJ45 Ethernet 10/100M
Power Supply
Power supply AC Input voltage, Volt(1-1) 380~415V AC
Power supply AC Input Frequency Range, Hz 50~60
Power supply AC Input current, Amp(1-2) 63
Water pump
Rated power, W 450
Noise, dBA@1m 60
Lift, m 19
Size (Length*Width* Height), mm 360*210*268
Plate heat exchanger
Maximum heat exchange power, kW 30
Size (Length*Width* Height), mm 305*106*64
Diameter of water pipe connector, mm DN20
Part 2: External Cooler(1-3)
Hardware Configuration
Size (Length*Width*Height), mm (without package) 1160*1035*1570
Size (Length*Width*Height), mm (with package) 1310*1185*1770
Net weight, kg (without package) 380
Gross weight, kg (with package) 432
Power supply
Power supply AC input voltage, Volt(1-1) 380~415V AC
Power supply AC input frequency range, Hz 50~60
Maximum power supply AC input current, Amp(1-2) 63
Heat pump
Heating Capacity (typical), kW 32
Compressor Input (typical), kW 8
EER (typical) 3
Sound Level, Db(A) 77
Refrigerant R134a
Heating water outlet temperature, °C 80
Fan
Rated power, W 1900
Noise, dBA@1m 74
Size (Length*Height*Thickness), mm 1010*1010*369
Water pump
Rated power, W 370
Noise, dBA@1m 74
Size (Length*Width* Height), mm 328*205*461
Environment Requirements
Ambient temperature, °C -20~45
Water flow, L/min 32.0~40.0 (Cabinet side)
Water pressure, bar ≤3.5
Working fluid(1-4) Antifreeze (10%)
Installation distance, m(1-5) 50
Liquid PH 7.8~8.5
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

Notes:

(1-1) Caution: Wrong input voltage may probably cause miner damaged.

(1-2) Three-phase AC input.

(1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment.

(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

(1-5) The distance between mining cabinet and external cooler.

 

Categories: ,